Thrombin recombinant

Preview FDA label, Baxter Healthcare Corporation, effective 2025-06-09. Full label on DailyMed

Patient handout

Looking up MedlinePlus…

From MedlinePlus, U.S. National Library of Medicine

Quoted from the FDA label. Product labels differ by manufacturer and change over time; confirm against the label for the product you are using. Not yet reviewed by a ClinDose pharmacist.

Dosing in kidney impairment

This label has no separate kidney-impairment dosing section. Check warnings and clinical pharmacology in the full label.

Preparation and administration

Prepare this dose

Your numbers for thrombin recombinant. Take vial strength, diluent, and limits from the label below.

Basis

Enter a dose to see draw volume, final concentration, and rates.

Reconstitution of RECOTHROM Thrombin The volume of reconstituted RECOTHROM Thrombin topical (Recombinant) required will vary depending on the size and number of bleeding sites to be treated and the method of application. Inspect the integrity of the RECOTHROM package and contents. Do not use if the packaging or contents have been damaged or opened.

Reconstitute the lyophilized powder using the supplied diluent. Use aseptic technique when handling vials and syringes. 5,000-unit RECOTHROM Thrombin topical (Recombinant) Reconstitution Units used herein represent international units of potency determined using a reference standard that has been calibrated against the World Health Organization Second International Standard for Thrombin. 1.

Remove flip-off cap from the top of the RECOTHROM vial. 2. Attach the needle-free vial access device (VAD) and snap it into place on the vial by placing the vial on a flat surface and pushing the VAD straight down into the center of the vial stopper. 3. Attach the prefilled diluent syringe to the VAD. 4. Transfer the 5 mL of diluent from the syringe into the RECOTHROM vial. 5.

DO NOT reuse the diluent syringe for transfer of the reconstituted product. Remove and discard the diluent syringe. 6. Gently swirl and invert the RECOTHROM vial until the powder is completely dissolved. Avoid excessive agitation. The powder should dissolve in less than one minute at room temperature. RECOTHROM solution should remain in the vial until ready for transfer to a labeled sterile bowl or basin. 7.

Withdraw reconstituted RECOTHROM solution into transfer syringe labeled For topical use only, DO NOT INJECT. Transfer RECOTHROM solution into a labeled sterile bowl or basin. 8. RECOTHROM is ready for application. RECOTHROM is for topical use only – DO NOT INJECT. See Application techniques below. RECOTHROM is for single use only.

Discard unused contents. 20,000-unit RECOTHROM Thrombin topical (Recombinant) Reconstitution 1. Remove the flip-off cap from the top of the RECOTHROM vial and the diluent vial. 2. There are two needle-free vial access devices (VADs) provided. Attach one VAD to the RECOTHROM vial and one VAD to the diluent vial. To attach a VAD to a vial, place the vial on a flat surface and push straight down on the VAD into the center of the vial stopper. 3.

Attach the empty 20-mL transfer syringe to the VAD on the diluent vial (injection of air into the diluent vial may facilitate withdrawal of the diluent). This syringe will be used twice: 1. To draw up the diluent from the diluent vial to be transferred into the RECOTHROM vial for reconstitution and 2. To draw up the reconstituted RECOTHROM solution. 4.

Draw up 20 mL of diluent from the vial into the syringe. 5. Remove the diluent-filled syringe from the diluent vial and attach the syringe to the VAD on the RECOTHROM vial. 6. Transfer the 20 mL of diluent from the syringe into the RECOTHROM vial. 7. Leave the syringe attached and gently swirl and invert the RECOTHROM vial until the powder is completely dissolved.

Avoid excessive agitation. The powder should dissolve in less than one minute at room temperature. RECOTHROM solution should remain in the vial until ready for transfer to a labeled sterile bowl or basin. 8. Withdraw reconstituted RECOTHROM solution into the attached transfer syringe labeled For topical use only, DO NOT INJECT.

Use the transfer syringe for immediate transfer of RECOTHROM solution into a labeled sterile bowl or basin. 9. RECOTHROM is ready for application. RECOTHROM is for topical use only—DO NOT INJECT. See Application Techniques below. RECOTHROM vial is for single use only. Discard unused contents.

Contraindications

4 CONTRAINDICATIONS • Do not inject directly into the circulatory system. • Do not use for the treatment of massive or brisk arterial bleeding. • Do not administer to patients with a history of hypersensitivity to RECOTHROM Thrombin topical (Recombinant) or any components of RECOTHROM. • Do not use in patients with known hypersensitivity to hamster proteins. • Do not inject directly into the circulatory system. (4) • Do not use for the treatment of massive or brisk arterial bleeding. (4) • Do not administer to patients with a history of hypersensitivity to RECOTHROM Thrombin topical (Recombinant), any components of RECOTHROM or hamster proteins. (4)

Pregnancy and lactation

Pregnancy

8.1 Pregnancy Risk Summary There are no available data regarding RECOTHROM Thrombin topical (Recombinant) in pregnant women. No animal reproductive and developmental toxicity studies have been conducted with RECOTHROM. In the U.S. general population, the estimated background risk of major birth defects and miscarriage in clinically recognized pregnancies is 2-4% and 15-20%, respectively.

For breastfeeding, also see LactMed (National Library of Medicine), which summarizes milk levels and infant effects.

Supply and cost

Drug shortage status

Loading

Recalls (last 24 months)

Loading

Therapeutic equivalence (Orange Book)

Loading

Price ladder

Not the price at the counter
Loading

These are not what a patient pays at the pharmacy counter. They are what pharmacies, health plans, and government buyers pay, before manufacturer rebates. A patient's cost depends on their insurance (copay, coinsurance, or deductible) or the pharmacy's cash price.